DWM-IV / DBC-A DIGITAL BATCH CONTROLLER
EXPRESS SYSTEM 201 SEQUENCE OF OPERATION
 
 

 

 
 

Weigh (two speed feed), Print, Hold, Reset

Two speed feed may be Parallel Fast / Slow, or Sequential Fast / Slow.

Two speed feed may be disabled (single speed feed).

Automatic Print may be disabled.


 
  Automatic Batching Cycle:

 
 
  1. Press START.

  2. FAST FEED will begin IF starting from a previous Cycle Complete OR from a previous mid-cycle STOP.

  3. When the batch weight increases to a preselected weight set-point, FAST FEED will stop and SLOW FEED will begin.

  4. When the batch weight increases to a preselected final cutoff point, SLOW FEED will stop, ending the batch filling cycle, and placing the sequence at Hold.

    NOTE: If optional multi-ingredient sequences are utilized, the FAST FEED / SLOW FEED for the second ingredient will begin prior to Hold. Upon the completion of the second ingredient's batch fill, the third ingredient will repeat the sequence, etc..

  5. Upon completion of the feed cycle the batch weight will automatically transmit to a printer, and be stored in internal memory for later retrieval as a production summary and material usage report.

    NOTE: If optional multi-ingredient sequences are utilized, EACH ingredient's batch weight will transmit, along with the accumulated batch weight. The internal memory will store the accumulated weight of each ingredient and the accumulated weight of all batches.

  6. The user manually discharges the batch from the scale.

  7. Cycle Complete is caused when the weight in the scale returns to below a Zero Tolerance Threshold.

  8. Upon Cycle Complete, the system will Reset for the next cycle, beginning with Step #1.

 
 
Push OFF at any time to immediately STOP the batch sequence. The user will then have the option to continue where the sequence left off, or to abort the sequence.

 
 
 
 

     Back to Express System 201 Page

 
     