AUTOMATIC FLIP-FLOP TWO
SCALE SYSTEM
(2 speed feed)
EXPRESS SYSTEM 303 SEQUENCE OF OPERATION

 
 

 

 
 

Tare A, Tare B; Feed A, Slow Feed A & B, Fast Feed B, Slow Feed A & B.

  1. Place an empty container on scale (or both scale) and switch ON/OFF to ON.

  2. Empty container(s) will satisfy "container in place" weight threshold interlock. Witch causes Automatic Tare to Net Weight Zero, witch then sets the scale to run it's logic sequence.

  3. Press START to begin production. The system will turn on the feed pump and begin product flow.


  4. Simultaneous with feed pump start, Scale A feed valve will open and begin Fast Feed.

  5. Scale A Fast Feed will continue until the Slow Feed weight set-point is achieved, at witch time the Scale B feed valve are open. At this point, both the Scale A and Scale B feed valves are open. Because product flow rate is provided at a continuous rate by the pump, and because the flow rate is split between the two valves; the effect is Slow feed (at approximately 50% of Fast Feed) to both Scales A & B. Scale A is being "topped off" at Slow Feed, Scale B is being initially filled at Slow Feed. The result is a constant product flow rate thought the Scale A Slow Feed cycle.

  6. When Scale a fills to it's Final weight set-point, the Scale A valve is turned off, resulting in fast Feed on Scale B. Scale a has completed its fill cycle.

  7. Remove the fill container from Scale A Scale A will return to Zero, instantly resetting for a new cycle. Placing a new empty container on scale a will once again satisfy the "container in place" weight threshold interlock which causes Automatic Tare to Net Weight Zero. Scale a is now ready to receive the flip-flop command to receive fill when Scale B goes to Slow Feed (witch again opens both valves).

  8. The flip-flop sequence between the two scales will continue unless:

    A. The Stop button is pressed, which closes any open valves, which then causes a "both valves closed" interlock to stop the pump. Press START to resume a "both valves closed" interlock to stop the pump. Press START to resume the process where it left off, or, Press the RESET key on the keypad if it is desired to cancel cycles in progress and start over.

    B. IF a full container is remaining on scale, or IF no container is detected on the scale through the "container in place" interlock, feed will be prevented from switching to the scale. In either of these cases, the pump will be turned off. Removing the full container and (or) placing a new empty container will automatically cause the system to resume where it left off.

 

 
 
 
 

     Back to Express System 303 Page

 
     