DWM-IV / NWF-A NET WEIGHT FILLER
EXPRESS SYSTEM 101 SEQUENCE OF OPERATION
 
 

 

 
 

   Tare, Weigh (2 speed feed), Print, Hold, Reset

    Automatic Tare may be disabled.

    2 speed feed may be Parallel

    Fast/Slow or Sequential Fast/Slow.

    2 speed feed may be disabled (single speed feed).

    Automatic Print may be disabled

 
 
  1. Place an empty container on the scale, and Press START.

    a. If the "empty container in place" weight threshold is satisfied, the scale will automatically Tare the empty container to Net Weight Zero, then start FAST FEED.

    b. If the "empty container in place" weight threshold does not detect an empty container, or if a full container is still detected on the scale, then start of a new filling cycle will be inhibited.

  2. When the Net Weight filling into the container reaches a preselected weight, FAST FEED will stop and SLOW FEED will start.

  3. When the Net Weight filling into the container reaches a preselected cutoff weight, SLOW FEED will stop.

  4. The filled container's Net Weight will automatically transmit to a printer and be accumulated internally to memory for later retrieval visually or as a printable transmission.

  5. As soon as the filled Net Weight container is removed from the scale, the cycle will Reset, and the process can begin at Step #1 again.

 
 

If at any time during the cycle, the ON / OFF mushroom switch is pushed OFF, the fill cycle will immediately halt.

 
 
  1. To resume the cycle from where it left off: Pull the mushroom switch ON, then Press START.

  2. To abort the cycle: Clear the scale of incomplete containers, then press RESET on the keypad, then pull the mushroom switch ON. The cycle can now resume from Step #1.

 
 
 
 